The Accuracy of 3D Printed Carpal Bones Generated from Cadaveric Specimens

Document Type : RESEARCH PAPER

Authors

1 Rowan University School of Osteopathic Medicine, Stratford, NJ, USA

2 Department of Hand & Upper Extremity Surgery, Thomas Jefferson University, Philadelphia, PA, USA

3 Department of Radiology, Thomas Jefferson University Hospitals, Cherry Hill, NJ, USA

Abstract

Background: Computer assisted three-dimensional (3D) printing of anatomic models using advanced imaging has
wide applications within orthopaedics. The purpose of this study is to evaluate the 3D printing accuracy of carpal
bones.
Methods: Seven cadaveric wrists underwent CT scanning, after which select carpal bones (scaphoid, capitate, lunate,
and trapezium) were dissected in toto. Dimensions including length, circumference, and volume were measured directly
from the cadaver bones. The CT images were converted into 3D printable stereolithography (STL) files. The STL files
were converted into solid prints using a commercially available 3D printer. The 3D printed models’ dimensions were
measured and compared to those of the cadaver bones. A paired t-test was performed to determine if a statistically
significant difference existed between the mean measurements of the cadavers and 3D printed models. The intraclass
correlation coefficients (ICC) between the two groups were calculated to measure the degree of agreement.
Results: On average, the length and circumference of the 3D printed models were within 2.3 mm and 2.2 mm,
respectively, of the cadaveric bones. There was a larger discrepancy in the volume measured, which on average was
within 0.65 cc (15.9%) of the cadaveric bones. These differences were not statistically significant (P > 0.05). There
was strong agreement between all measurements except the capitate’s length and lunate’s volume.
Conclusion: 3D printing can add value to patient care and improve outcomes. This study demonstrates that 3D printing
can both accurately and reproducibly fabricate boney models that closely resemble the corresponding cadaveric anatomy.
Level of evidence: V

Keywords


1. Eltorai AEM, Nguyen E, Daniels AH. Three-
Dimensional Printing in Orthopedic Surgery.
Orthopedics. 2015;38(11):684-687
2. Liaw CY, Guvendiren M. Current and emerging
applications of 3D printing in medicine. Biofabrication.
2017;9(2):024102
3. Galvez M, Asahi T, Baar A, Carcuro G, Cuchacovich N,
Fuentes JA, et al. Use of Three-dimensional Printing
in Orthopaedic Surgical Planning. J Am Acad Orthop
Surg Glob Res Rev. 2018;2(5):e071
4. George E, Liacouras P, Rybicki FJ, Mitsouras D.
Measuring and Establishing the Accuracy and
Reproducibility of 3D Printed Medical Models.
Radiographics. 2017;37(5):1424-1450
5. Ogden KM, Aslan C, Ordway N, Diallo D, Tillapaugh-Fay
G, Soman P. Factors Affecting Dimensional Accuracy
of 3-D Printed Anatomical Structures Derived from
CT Data. J Digit Imaging. 2015;28(6):654-663
6. Wu AM, Shao ZX, Wang JS, Yang XD, Weng WQ, Wang
XY, et al. The accuracy of a method for printing
three-dimensional spinal models. PLoS ONE.
2015;10(4):e0124291
7. Fishman, EK (1999). Siemens Sensation 16 - CT Protocols
- CTisus.com CT Scanning. CTisus. https:// www.ctisus.
com/responsive/protocols/siemens?sensation-16
8. Vaish A, Vaish R. 3D printing and its applications in
Orthopedics. J Clin Orthop Trauma. 2018;9(Suppl
1):S74-S75
9. Zambouri A. Preoperative evaluation and preparation
for anesthesia and surgery. Hippokratia.
2007;11(1):13-21.
10. Guo F, Dai J, Zhang J, Ma Y, Zhu G, Shen J, et al.
Individualized 3D printing navigation template for
pedicle screw fixation in upper cervical spine. PLoS
ONE. 2017;12:e0171509.
11. Zheng W, Su J, Cai L, Lou Y, Wang J, Guo X, et al.
Application of 3D-printing technology in the
treatment of humeral intercondylar fractures.
Orthop Traumatol Surg Res. 2018;104:83–8.
12. Huotilainen E, Jaanimets R, Valášek J, Marcian P,
Salmi M, Tuomi J, et al. Inaccuracies in additive
manufactured medical skull models caused by the
DICOM to STL conversion process. J Craniomaxillofac
Surg. 2014;42(5):e259-265
13. Schweizer A, Mauler F, Vlachopoulos L, Nagy L,
Fürnstahl P. Computer-Assisted 3-Dimensional 
Reconstructions of Scaphoid Fractures and Nonunions
With and Without the Use of Patient-Specific
Guides: Early Clinical Outcomes and Postoperative
Assessments of Reconstruction Accuracy. J Hand Surg
Am. 2016;41(1):59-69
14. Heinzelmann AD, Archer G, Bindra RR. Anthropometry
of the human scaphoid. J Hand Surg Am.
2007;32(7):1005-1008
15. Vaezi T, Hassankhani GG, Ebrahimzadeh MH, Moradi
A. Evaluation of Normal Ranges of Wrist Radiologic
Indexes in Mashhad Population. Arch Bone Jt Surg.
2017;5(6):451-458.
16. Ballard DH, Mills P, Duszak R, Weisman JA, Rybicki
FJ, Woodard PK. Medical 3D Printing Cost-Savings in
Orthopedic and Maxillofacial Surgery: Cost Analysis
of Operating Room Time Saved with 3D Printed
Anatomic Models and Surgical Guides. Academic
Radiology. 2020;27:1103–13.