Biomechanical Evaluation of Temperature Rising and Applied Force in Controlled Cortical Bone Drilling: an Animal in Vitro Study

Document Type : RESEARCH PAPER

Authors

1 Department of Orthopedic Surgery, School of Medicine, AJA University of Medical Science, Tehran, Iran

2 School of Dentistry, Tehran University of Medical Science, Tehran, Iran

Abstract

Background: The present study was conducted to quantify the relationships between bone drilling process parameters
(i.e., feed rate, resting time, exit rate, and drill bit diameter) and drilling outcome parameters (i.e., thrust force and
maximum temperature).
Methods: This study utilized 10-cm cortical bovine samples to evaluate the effects of four independent parameters,
including drill bit diameters, six different feed rates, three various resting times, and three different exit rates on thrust
force and maximum temperature (MT). A total of 28 stainless steel orthopedic drill bits with a diameter of 2.5 and 3.2
mm, as well as an orthopedic handpiece were attached to the 500N load cell and an accurate linear variable differential
transformer to obtain forces. Moreover, two k-type thermocouples were utilized to record the temperature-time curve
near the drilling site. The data were analyzed using the two-way analysis of variance and post hoc Tukey-Kramer
Honest test.
Results: Maximum thrust force (MTF) decreased by almost 230% as the drill bit diameter increased from 2.5 to 3.2
mm in the lowest feed rate. The MTF showed a 335% increase, whereas a decrease of 69% was observed as the feed
rates rose from 0.5 to 3 mm/sec. Moreover, the MT decreased to 67% with an increasing exit rate from 1 to 3 mm/sec.
Furthermore, a slight increase was observed in MT when the resting time increased from 0 to 2 seconds (P>0.05).
Conclusion: The desired drilling is drilling with lower thrust force and lower final temperature of bone. Increasing feed
rate can cause an increase and decline in thrust force and final temperature, respectively. The highest rates of MT were
0.5 and 1 mm/min, and the optimum feed rate would be 1.5 mm/min due to the averaged thrust force. Moreover, the
resting time had no significant effects on the final temperature. Attentions to resting time would be useful to provide a
more accurate, efficient, and uniform drill hole.
Level of evidence: V

Keywords


1. Augustin G, Zigman T, Davila S, Udilljak T, Staroveski
T, Brezak D, et al. Cortical bone drilling and
thermal osteonecrosis. J Clinical biomechanics.
2012;27(4):313-25.
2. Pandey RK, Panda S. Drilling of bone: A comprehensive
review. Journal of clinical orthopaedics trauma
2013;4(1):15-30.
3. Lee J, Chavez CL, Park J. Parameters affecting
mechanical and thermal responses in bone drilling: A
review. Journal of biomechanics. 2018;71:4-21.
4. Shahrezaee M, Oryan A, Bastami F, Hosseinpour S,
Shahrezaee MH, Kamali AJE. Comparative impact
of systemic delivery of atorvastatin, simvastatin,
and lovastatin on bone mineral density of the
ovariectomized rats. 2018;60(1):138-50.
5. Augustin G, Davila S, Mihoci K, Udiljak T, Vedrina DS,
Antabak A. Thermal osteonecrosis and bone drilling
parameters revisited. J Archives of orthopaedic
trauma surgery 2008;128(1):71-7.
6. Bachus KN, Rondina MT, Hutchinson DT. The effects
of drilling force on cortical temperatures and their
duration: an in vitro study. J Medical engineering
physics 2000;22(10):685-91.
7. Eriksson R, Albrektsson T, Magnusson B. Assessment
of bone viability after heat trauma: a histological,
histochemical and vital microscopic study in the
rabbit. Scandinavian journal of plastic reconstructive
surgery. 1984;18(3):261-8.
8. Lee J, Ozdoganlar OB, Rabin Y. An experimental
investigation on thermal exposure during bone drilling.
J Medical engineering physics 2012;34(10):1510-20.
9. Qi L, Wang X, Meng MQ. 3D finite element modeling
and analysis of dynamic force in bone drilling for
orthopedic surgery. J International journal for
numerical methods in biomedical engineering. 2014;
30(9):845-56.
10. Alam K, Mitrofanov A, Silberschmidt VV. Experimental
investigations of forces and torque in conventional
and ultrasonically-assisted drilling of cortical bone. J
Medical engineering physics 2011;33(2):234-9.
11. Sui J, Sugita N. Experimental Study of Thrust Force
and Torque for Drilling Cortical Bone. J Annals of
biomedical engineering. 2019;47(3):802-12.
12. Lee J, Gozen BA, Ozdoganlar OB. Modeling and
experimentation of bone drilling forces. Journal of
biomechanics. 2012;45(6):1076-83.
13. Alam K, Muhammad R, Shamsuzzoha A, AlYahmadi A,
Ahmed N. Quantitative analysis of force and torque in
bone drilling. The Journal of Engineering Research.
2017;14(1):39-48.
14. Lughmani WA, Bouazza-Marouf K, Ashcroft I, editors.
Finite element modeling and experimentation of bone
drilling forces. Journal of Physics: Conference Series;
2013: IOP Publishing.
15. Tuijthof G, Frühwirt C, Kment C. Influence of tool
geometry on drilling performance of cortical and
trabecular bone. J Medical engineering physics 
2013;35(8):1165-72.
16. Hein C, Inceoglu S, Juma D, Zuckerman L. Heat
generation during bone drilling: a comparison
between industrial and orthopaedic drill bits. Journal
of orthopaedic trauma. 2017;31(2):e55-e9.
17. Fincham BM, Jaeblon T. The effect of drill bit, pin, and
wire tip design on drilling. Journal of the American
Academy of Orthopaedic Surgeons. 2011;19(9):574-9.
18. Karmani S, Lam F. The design and function of
surgical drills and K-wires. J Current Orthopaedics.
2004;18(6):484-90.
19. Paszenda Z, Basiaga M. FEM analysis of drills used
in bone surgery. J Archives of Materials Science
Engineering 2009;36(2):103-9.
20. Kim S-J, Yoo J, Kim Y-S, Shin S-W. Temperature change
in pig rib bone during implant site preparation by
low-speed drilling. Journal of Applied Oral Science.
2010;18(5):522-7.
21. Fernandes MG, Fonseca EM, Natal RM. Threedimensional
dynamic finite element and experimental
models for drilling processes. Journal of Materials:
Design Applications 2018;232(1):35-43.
22. Chen Y-C, Tu Y-K, Zhuang J-Y, Tsai Y-J, Yen C-Y,
Hsiao C-K. Evaluation of the parameters affecting
bone temperature during drilling using a threedimensional
dynamic elastoplastic finite element
model. J Medical biological engineering computing
2017;55(11):1949-57.
23. Alam K, Hassan E, Bahadur I. Experimental
measurements of temperatures in ultrasonically
assisted drilling of cortical bone. J Biotechnology
biotechnological equipment 2015;29(4):753-7.
24. An YH, Draughn RA. Mechanical testing of bone and
the bone-implant interface: CRC press; 1999.
25. Tu Y-K, Chen L-W, Ciou J-S, Hsiao C-K, Chen Y-C. Finite
element simulations of bone temperature rise during
bone drilling based on a bone analog. J Journal of
Medical Biological Engineering 2013;33(3):269-74.
26. Solgi S, Shahrezaee M, Zamanian A, Jafarzadeh Kashi
T, Raz M, Khoshroo K, et al., editors. Sol-gel synthesis
and characterization of SiO2-Cao-P2O5-SrO bioactive
glass: in vitro study. Key Engineering Materials; 2015:
Trans Tech Publ.
27. Lin Y, Chen H, Yu D, Zhang Y, Yuan W. A predictive
bone drilling force model for haptic rendering with
experimental validation using fresh cadaveric bone. J
International journal of computer assisted radiology
surgery. 2017;12(1):91-8.
28. Fernandes M, Fonseca E, Jorge RN, Vaz M, Dias
M. Thermal analysis in drilling of ex vivo bovine
bones. Journal of Mechanics in Medicine Biology
2017;17(05):1750082.
29. Einafshar MJ, Rouhi G, Aghighi M, Mortazavi SJ.
Alteration of the Thrust Force Versus Number of
Drill Bit Usage in Cortical Bone Drilling. Journal of
Orthopedic Spine Trauma 2016.
30. Dí􀆴az I, Gil JJ, Louredo M. Bone drilling methodology 
and tool based on position measurements. J
Computer methods programs in biomedicine
2013;112(2):284-92.
31. Wang W, Shi Y, Yang N, Yuan X. Experimental analysis of
drilling process in cortical bone. J Medical engineering
physics. 2014;36(2):261-6.
32. Karaca F, Aksakal BJAob, biomechanics. Effects
of various drilling parameters on bone during
implantology: An in vitro experimental study. j Acta of